Brand Name : Zhongdong
Model Number : YJV
Certification : ISO,CCC,CE,TUV
Place of Origin : Hebei,China
MOQ : Negotiable
Price : Negotiable
Payment Terms : L/C,T/T
Supply Ability : 100KM/Week
Delivery Time : 10work days
Packaging Details : Wooden Drum
Insulation Material : XLPE
Conductor Material : Copper or Aluminum
Jacket : PVC
Working Temperature : 90°C
Rated Voltage : 12/20kV
Color : Black
Medium voltage 3-core cables (typically rated from 6 kV to 36 kV) are widely used in power distribution networks due to their balanced phase loading, compact design, and enhanced reliability compared to single-core alternatives.
Conductor: Round compacted conductors
Conductor Shield: Semi conductive shielding material (below 500mm) Semi conductive tape+semi conductive shielding material (500mm and above)
Insulation: Polyvinyl chloride (PVC)
Insulation Shield: Peelable semiconducting shielding material
Metal Shield Layer: Copper Tape Copper Wire(35kV 500mm above)
Filler: Polypropylene(PP) mesh filling rope
Binder Tape: Non hygroscopic straps
Armouring: Steel Tape(Single core) Galvanized steel tape(3 core)
Outer sheath: 90℃ Polyvinyl chloride (PVC)
Voltage Rating Uo/U
3.6/6(7.2)kV, 6/6(7.2)kV,6/10(12)kV, 8.7/10(12)kV,
8.7/15(17.5)kV, 12/20(24)kV, 18/20(24)kV,
18/30(36)kV, 21/35(40.5) kV, 26/35(40.5)kV
Temperature Rating
Maximum operating temperature of conductor:+90℃
Operating ambient temperature: -15℃~+55℃
Cable laying temperature:Not less than 0℃(When the ambient temperature is below 0℃, the cable should be preheated.)
Minimum Bending Radius
Single Core 15D
Three Core 12D
(D is the actual outer diameter of the cable)
GB/T12706.2-2020, GB/T 12706.3-2020
Specs | Conductor diameter | Outer thickness of insulation | Approx outer diameter of cable | Approx cable weight |
3×35 | 6.6±0.2 | 20.0 | 54.1 | 3935 |
3×50 | 7.6±0.2 | 21.0 | 56.6 | 4480 |
3×70 | 9.2±0.2 | 22.6 | 60.2 | 5336 |
3×95 | 10.9±0.2 | 24.3 | 64.2 | 6387 |
3×120 | 12.2±0.2 | 25.6 | 67.3 | 7326 |
3×150 | 13.6±0.2 | 27.0 | 70.6 | 8340 |
3×185 | 15.2±0.2 | 28.6 | 74.5 | 9705 |
3×240 | 17.4±0.2 | 30.8 | 81.0 | 12490 |
3×300 | 19.5±0.2 | 32.9 | 85.9 | 14635 |
3×400 | 22.0±0.2 | 35.4 | 91.9 | 17515 |
3×500 | 24.8±0.2 | 39.0 | 100.2 | 21345 |
3×630 | 28.2±0.2 | 42.4 | 108.1 | 26055 |
Q: What are the core configurations for 3-phase power transmission?
A: Common options include:
Three single-core cables (installed in trefoil or flat formation)
One 3-core cable with shared armor (cost-effective for shorter runs).
Q: How to select cable cross-section for a given current load?
A: Use the formula:
[ I = frac{P}{sqrt{3} times V times cosphi} ]
Where I is current, P is power, V is voltage, and (cosphi) is power factor. Consult IEEE 835 for derating factors.
Q: . What is the maximum allowable bending radius?
A: For steel-wire-armored (SWA) cables, the minimum bending radius is 12× cable diameter (dynamic) or 6× (static).
Q: . Can armored cables be used in underground ducts?
A: Yes, but ensure duct sizing allows for bending radius and consider earth fault current path. Non-metallic ducts may require additional earthing.
Q: . How to terminate armored MV cables?
A: Use armor clamping kits and stress cones for XLPE cables. Follow manufacturer guidelines to avoid corona discharge.
Q:. What maintenance is required for armored MV cables?
Annual IR testing (insulation resistance >1000 MΩ/km)
Thermal imaging to detect hotspots
Armor integrity checks for corrosion.
Q: . Are there environmental restrictions for installation?
A: Avoid direct sunlight for non-UV-resistant jackets. For wet conditions, specify water-blocking tape or lead sheath.
![]() |
6kV - 35kV Medium Voltage Cable 3c X 95mm 120mm 150mm 185mm 240mm 300mm 400mm MV Power Cable Images |